145W Single Output Switching Power Supply
Basic Info
Model No.: S-145
Product Description
2. Universal AC input / Full range
3. 100% full load burn-in test
4. Protections: Short circuit/Over load/ Over voltage |
|
Specification: |
Model | S-145-5 | S-145-7.5 | S-145-12 | S-145-15 | S-145-24 | |
Output | DC voltage | 5V | 7.5V | 12V | 15V | 24V |
Voltage tolerance | ±2% | ±1% | ±1% | ±1% | ±1% | |
Rated current | 25A | 18A | 12A | 9.6A | 6A | |
Current range | 0-25A | 0-18A | 0-12A | 0-9.6A | 0-6A | |
Rated power | 125W | 135W | 144W | 144W | 144W | |
Ripple & noise | 100mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | |
DC adjustment range | ±10% | -20%,+10% | -12%,+10% | -12%,+10% | -12%,+16% | |
Setup, rise, hold time | 100ms,50ms,20ms at full load | |||||
Input | Voltage range | 88~132 VAC/176~264VAC 47~63 Hz; | ||||
AC current | 3.2A/115 V 1.6A/ 230 V | |||||
Efficiency | 78% | 80.5% | 80.5% | 81% | 83.5% | |
Inrush current | Cold start 35A/230VAC | |||||
Leakage current | ||||||
Protection | Over load | 135%~165% | ||||
Protection type: Shut down o/p voltage, re-power on to recover | ||||||
Over voltage | 115%~135% | |||||
Protection type: Shut down o/p voltage, re-power on to recover | ||||||
Environment | Working temp. & humidity | -10°C~+60°C;20%~90 %RH | ||||
Storage temp. & humidity | -20°C~+85°C;10%~95 %RH | |||||
Vibration | 10~500Hz,2G 10min./1cycle,period for 60min, each along X, Y, Z axes | |||||
Safety | Withstand voltage | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | ||||
Isolation resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | |||||
Standard | Safety standard | Design refer to UL1012 | ||||
EMC standard | Design refer to EN55022,IEC801-2,3,4 | |||||
Others | Weight | 0.71Kg | ||||
Packing | 30pcs/22.5kg/1.22CUFT | |||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. |
Product Categories : Switching Power Supply